Error Reporting
HIL includes a centralized error reporting system that collects, categorizes, and tracks errors from all connected devices and software components (Musa, 1999).
Error Reporting Architecture
Error Types
| Type | Description | Example |
|---|---|---|
compile | Syntax or parse error | Missing parenthesis, unknown operator |
runtime | Execution error | Division by zero, stack overflow |
hardware | Hardware communication error | Serial timeout, CRC mismatch |
network | Network/IoT error | MQTT disconnect, HTTP timeout |
package | Package loading error | Module not found, version conflict |
Error Object Structure
{
"id": "err-001",
"timestamp": "2026-01-15T10:30:00Z",
"error_type": "runtime",
"message": "Stack overflow in recursive function",
"device_id": "hil-device-001",
"context": {
"expression": "(FACT 100000)",
"line": 5,
"function": "FACT"
},
"resolved": false,
"resolution": null
}
Reporting Errors via API
Report an Error
curl -X POST http://localhost:3002/api/errors \
-H "Content-Type: application/json" \
-d '{
"device_id": "hil-device-001",
"error_type": "runtime",
"message": "ADC overflow on pin A0"
}'
Query Errors
# Get all errors
curl http://localhost:3002/api/errors
# Response:
{
"errors": [
{
"id": "err-001",
"timestamp": "2026-01-15T10:30:00Z",
"error_type": "runtime",
"message": "ADC overflow on pin A0",
"device_id": "hil-device-001",
"resolved": false
}
],
"total": 1
}
Get Error Statistics
curl http://localhost:3002/api/errors/stats
# Response:
{
"total": 15,
"byType": {
"compile": 3,
"runtime": 8,
"hardware": 2,
"network": 1,
"package": 1
},
"byDevice": {
"hil-device-001": 10,
"hil-device-002": 5
},
"byHour": {
"2026-01-15T10": 5,
"2026-01-15T11": 10
}
}
Error Handling in HIL LISP
Try-Catch Pattern
HIL LISP handles errors gracefully in the REPL evaluator. The DO block stops execution on error, and the error is logged:
; Division by zero is safe (returns 0)
(/ 10 0) ; 0
; Stack overflow is caught
(DEFUN INFINITE () (INFINITE))
(INFINITE) ; Error: stack overflow
Defensive Programming
Use IF to validate inputs before operations:
; Safe division
(DEFUN SAFE-DIV (a b)
(IF (== b 0) 0 (/ a b)))
; Safe sensor read with validation
(DEFUN SAFE-READ (pin)
(DO
(SET val (READ A pin))
(IF (AND (>= val 0) (<= val 1023)) val 0)))
Error Recovery in Loops
; Monitor with error recovery
(SET error-count 0)
(WHILE (< error-count 5)
(DO
(SET temp (READ A 0))
(IF (OR (< temp 0) (> temp 1023))
(DO
(SET error-count (+ error-count 1))
(LOG "ADC error #" error-count))
(DO
(SET error-count 0)
(LOG "Temperature: " (/ temp 4) "C")))
(DELAY 1000)))
Error Severity
| Severity | Description | Typical Type |
|---|---|---|
| High | System-critical failure | compile, hardware |
| Medium | Recoverable error | runtime |
| Low | Informational | network, package |
Error Resolution
Errors can be marked as resolved through the API or admin panel:
# Mark error as resolved
curl -X PUT http://localhost:3002/api/errors/err-001 \
-H "Content-Type: application/json" \
-d '{"resolved": true, "resolution": "Replaced sensor module"}'
Diagnostics
The system provides diagnostic information for debugging:
References
Musa, J. D. (1999). Software reliability engineering. McGraw-Hill.