Skip to main content

Microservices Architecture

HIL OS can be deployed as a suite of microservices designed for large-scale IoT fleet management. This architecture separates concerns into independently deployable services communicating through MQTT, HTTP, and WebSocket protocols.

Why Microservices for IoT?​

The Monolith Problem​

A single HIL process works well for prototyping and small deployments. As fleet sizes grow beyond 50 devices, a monolithic approach faces several challenges:

  • Coupled scaling: CPU-intensive telemetry processing cannot scale independently from API request handling
  • Single point of failure: A crash in the OTA updater takes down device monitoring
  • Resource contention: Firmware uploads compete with real-time sensor data for processing time
  • Deployment risk: Updating one feature requires restarting the entire system
  • Team boundaries: Multiple developers modifying the same codebase creates merge conflicts

The Microservices Solution​

Decomposing HIL into services solves these problems:

ConcernMonolithMicroservices
ScalingVertical onlyHorizontal per-service
Failure isolationTotal outageBlast radius contained
DeploymentAll-or-nothingIndependent per-service
TechnologySingle languagePolyglot per-service
Team structureShared codebaseService ownership

When to Use Microservices​

Microservices are appropriate when:

  • Fleet size exceeds 100 devices
  • Multiple teams need to develop independently
  • Different services have different scaling requirements
  • High availability is critical (99.9%+ uptime)
  • You need regional deployment (edge + cloud)

For smaller deployments (under 50 devices), the monolithic HIL runtime is simpler and more efficient.

Architecture Overview​

The HIL microservices architecture consists of seven core components connected through an MQTT message bus:

Design Principles​

  1. MQTT as the spine: All device communication flows through MQTT. Services publish and subscribe to topics rather than calling each other directly.

  2. Single responsibility: Each service does one thing well. The Gateway handles HTTP routing. The Fleet manager tracks device state. The Telemetry service processes sensor data.

  3. Shared-nothing storage: Each service owns its data. Redis for registry and cache. InfluxDB for time series. SQLite for local aggregations. No shared databases.

  4. Graceful degradation: If one service goes down, others continue operating. The Fleet manager works even if Telemetry is down. Devices continue sending data through MQTT regardless of service health.

  5. Observable by default: Every service exposes health checks, structured logs, and metrics endpoints.

Service Deep Dive​

API Gateway (hil-api-gateway)​

The API Gateway is the single entry point for all HTTP traffic. It translates RESTful HTTP requests into MQTT commands sent to devices, and routes responses back to clients.

Responsibilities:

  • HTTP route handling and request validation
  • API key authentication and rate limiting
  • HTTP-to-MQTT bridge for device commands
  • WebSocket stream for real-time data
  • Request/response correlation via unique IDs

Key Topics:

Topic PatternDirectionDescription
hil/device/{id}/commandPublishSend command to device
hil/device/{id}/responseSubscribeReceive device response
hil/device/{id}/statusSubscribeDevice state changes
hil/device/{id}/telemetrySubscribeReal-time sensor data
hil/events/#SubscribeSystem-wide events

How Request/Response Works:

When a client sends POST /eval/:deviceId, the Gateway:

  1. Generates a unique requestId
  2. Publishes { requestId, action, payload } to hil/device/{deviceId}/command
  3. Waits for a matching response on hil/device/{deviceId}/response
  4. Returns the response to the HTTP client (with 30s timeout)
// Internal flow (simplified)
const requestId = uuidv4();
mqttClient.publish(`hil/device/${deviceId}/command`, JSON.stringify({
requestId,
action: "eval",
payload: { code: "read(D13)" },
timestamp: Date.now()
}));

// Response arrives on subscription
mqttClient.on("message", (topic, payload) => {
const data = JSON.parse(payload);
if (data.requestId === requestId) {
resolve(data); // Send back to HTTP client
}
});

Rate Limiting:

The Gateway enforces per-client rate limiting using a sliding window algorithm:

  • Default: 100 requests per 60-second window
  • Configurable via RATE_LIMIT_MAX and RATE_LIMIT_WINDOW_MS
  • Returns 429 Too Many Requests with Retry-After header when exceeded

Device Fleet (hil-device-fleet)​

The Fleet service maintains a real-time registry of all HIL devices, tracking their online/offline status through MQTT heartbeats.

Responsibilities:

  • Device registration and deregistration
  • Heartbeat monitoring and offline detection
  • Group management (logical device groupings)
  • Capability-based device search
  • Fleet health dashboard

Heartbeat Protocol:

Every HIL device publishes heartbeats at a configurable interval (default: 10 seconds):

{
"rssi": -45,
"uptime": 3600,
"freeHeap": 28400,
"timestamp": 1699900000000
}

The Fleet service subscribes to hil/device/+/heartbeat and tracks the last heartbeat time for each device. If no heartbeat is received within the timeout window (default: 30 seconds), the device is marked offline.

Auto-Offline Detection:

Device publishes heartbeat → Fleet records timestamp
↓
30 seconds pass with no heartbeat
↓
Fleet marks device as "offline"
↓
Publishes hil/device/{id}/status: { state: "offline" }

Group Management:

Groups allow logical organization of devices:

# Create a group
curl -X POST http://localhost:4001/groups \
-H "Content-Type: application/json" \
-d '{
"groupName": "production-line-1",
"description": "PLCs on manufacturing line 1",
"deviceIds": ["hil-001", "hil-002", "hil-003"],
"tags": ["manufacturing", "critical"]
}'

# Query group devices
curl http://localhost:4001/groups/production-line-1

Fleet Dashboard:

The /dashboard endpoint returns a comprehensive fleet health overview:

{
"fleet": {
"total": 150,
"online": 142,
"offline": 8,
"onlinePercentage": "94.7%"
},
"distribution": {
"byType": { "hil-standard": 120, "hil-pro": 30 },
"byCapability": { "gpio": 150, "i2c": 80, "spi": 45 },
"byFirmware": { "2.1.0": 100, "2.0.5": 50 }
}
}

Telemetry Pipeline (hil-telemetry)​

The Telemetry service collects, aggregates, stores, and analyzes sensor data from all devices.

Responsibilities:

  • Subscribe to all sensor data topics
  • Time-window aggregation (1m, 5m, 1h)
  • Anomaly detection with configurable thresholds
  • Dual storage: InfluxDB (time series) + SQLite (aggregations)
  • Data retention and cleanup
  • CSV/JSON export

Data Flow:

Device publishes sensor data
↓
Telemetry receives on hil/device/+/telemetry
↓
┌───────────────────────────────────────┐
│ 1. Store raw reading in SQLite │
│ 2. Write to InfluxDB (time series) │
│ 3. Add to aggregation buffer │
│ 4. Run anomaly detection │
└───────────────────────────────────────┘
↓
Every 10 seconds: flush aggregation buffer
↓
┌───────────────────────────────────────┐
│ Compute min/max/avg for each window │
│ Store in telemetry_aggregations │
└───────────────────────────────────────┘

Anomaly Detection:

The service maintains configurable thresholds for common sensor types:

SensorMinMaxSeverity
Temperature-40125Critical
Humidity0100Warning
Voltage060Critical
Current-5050Warning
Pressure3001100Info
RPM020000Warning
Battery0100Warning
RSSI-1200Info

When a reading exceeds thresholds, an anomaly is:

  1. Stored in anomaly_log table
  2. Published to hil/events/anomaly MQTT topic
  3. Published to hil/device/{id}/anomaly for device-specific handling

Aggregation Windows:

WindowDurationUse Case
1 minuteReal-time dashboardsLive monitoring
5 minutesShort-term trendsAlerting rules
1 hourLong-term analysisHistorical reports

Data Retention:

Raw readings older than RETENTION_DAYS (default: 30) are automatically cleaned up hourly. Aggregations are retained longer since they represent summarized data.

OTA Service (hil-ota-service)​

The OTA (Over-The-Air) service manages firmware distribution across the device fleet with staged rollouts and automatic rollback.

Responsibilities:

  • Firmware upload and storage with SHA-256 checksums
  • Version management and tracking
  • Staged rollout campaigns (canary → percentage → full)
  • Progress tracking per device
  • Automatic rollback on failure
  • Firmware checksum verification

Staged Rollout Flow:

1. Upload firmware → stored with SHA-256 checksum
↓
2. Create campaign → target devices selected
↓
3. Canary phase → 5% of devices receive update
↓
4. Monitor for failures (configurable threshold: 10%)
↓
┌─── Success ───┐ ┌─── Failure ───┐
↓ │ ↓ │
5. Advance to │ Rollback all │
25% → 50% → │ canary devices │
100% │ │
↓ ↓
6. Campaign complete Campaign rolled back

Firmware Checksum Verification:

Every firmware upload is checksummed with SHA-256. Devices verify the checksum after download:

# Verify a firmware file
curl http://localhost:4003/firmware/{firmwareId}/checksum

# Response
{
"firmwareId": "abc-123",
"storedChecksum": "a1b2c3d4...",
"computedChecksum": "a1b2c3d4...",
"match": true
}

Rollback Mechanism:

Automatic rollback triggers when the failure rate exceeds 10% of completed updates during any stage. Manual rollback can also be triggered:

# Manual rollback
curl -X POST http://localhost:4003/campaigns/{campaignId}/rollback

# Response
{
"success": true,
"campaignId": "...",
"status": "rolled_back",
"rollbackCount": 42
}

MQTT-WebSocket Bridge (hil-mqtt-bridge)​

The Bridge service provides bidirectional translation between MQTT and WebSocket protocols, enabling web browsers and mobile apps to communicate with devices in real-time.

Responsibilities:

  • Bidirectional MQTT ↔ WebSocket translation
  • Topic subscription management per client
  • QoS level translation (WS QoS 0/1 → MQTT QoS 0/1/2)
  • Connection pooling and heartbeat monitoring
  • Max connection enforcement

WebSocket Protocol:

Clients connect to ws://host:80/ws (through nginx) and exchange JSON messages:

// Subscribe to device telemetry
ws.send(JSON.stringify({
type: "subscribe",
topics: ["hil/device/hil-001/telemetry", "hil/device/hil-001/status"],
qos: 1
}));

// Receive messages
ws.onmessage = (event) => {
const msg = JSON.parse(event.data);
if (msg.type === "message") {
console.log(`Topic: ${msg.topic}`, msg.payload);
}
};

// Publish to device
ws.send(JSON.stringify({
type: "publish",
topic: "hil/device/hil-001/command",
payload: { action: "read", pin: 13 },
qos: 1
}));

Message Format Normalization:

All messages flowing through the bridge are normalized to a consistent format:

{
"type": "message",
"topic": "hil/device/hil-001/telemetry",
"payload": { "temperature": 23.5, "humidity": 45 },
"timestamp": 1699900000000,
"size": 42
}

Docker Compose Quick Start​

Prerequisites​

  • Docker Engine 20.10+
  • Docker Compose v2+
  • 2GB RAM minimum (4GB recommended)
  • Ports 80, 1883, 6379, 8086 available

Start All Services​

cd microservices/

# Generate secure keys
export API_KEY=$(openssl rand -hex 32)
export JWT_SECRET=$(openssl rand -hex 32)

# Build and start
docker-compose up -d --build

# Watch startup logs
docker-compose logs -f

Verify Installation​

# Check all services are healthy
docker-compose ps

# Test API Gateway
curl -H "X-API-Key: $API_KEY" http://localhost/api/gateway/health

# Test Fleet Dashboard
curl http://localhost/api/fleet/dashboard

# Test Telemetry Stats
curl http://localhost/api/telemetry/stats

First Device Registration​

# Register a device
curl -X POST http://localhost/api/gateway/devices/register \
-H "X-API-Key: $API_KEY" \
-H "Content-Type: application/json" \
-d '{
"deviceId": "hil-demo-001",
"name": "Demo Sensor",
"type": "sensor-node",
"capabilities": ["gpio", "i2c", "temperature"],
"firmwareVersion": "2.1.0"
}'

# Check it appears in the fleet
curl -H "X-API-Key: $API_KEY" http://localhost/api/gateway/devices

# Execute code on it
curl -X POST http://localhost/api/gateway/eval/hil-demo-001 \
-H "X-API-Key: $API_KEY" \
-H "Content-Type: application/json" \
-d '{"code": "read(A0)", "language": "hil"}'

Service Communication Patterns​

Asynchronous MQTT (Primary)​

Most inter-service communication uses MQTT pub/sub. Services never call each other directly for device data:

Client → Gateway → MQTT → Device
Device → MQTT → Gateway → Client
Device → MQTT → Telemetry → InfluxDB
Device → MQTT → Fleet → Redis

Advantages:

  • Decoupled producers and consumers
  • Natural backpressure (MQTT queues messages)
  • Survives service restarts (QoS 1/2)
  • Fan-out to multiple consumers

Synchronous HTTP (Fleet Queries)​

The OTA service calls the Fleet service via HTTP when creating campaigns without explicit device targets:

OTA Service → HTTP GET → Fleet Service → Device list

This is the only synchronous inter-service call. It uses fetch() with a 5-second timeout.

WebSocket (Client Streaming)​

Real-time data flows from MQTT through the Bridge to WebSocket clients:

Device → MQTT → Bridge → WebSocket → Browser

The Bridge maintains persistent connections and translates protocols transparently.

Deployment Scenarios​

Smart Home (50 Devices)​

A smart home deployment with 50 IoT devices:

# docker-compose.override.yml for smart home
services:
hil-api-gateway:
deploy:
resources:
limits: { memory: 256M, cpus: "0.5" }
hil-device-fleet:
deploy:
resources:
limits: { memory: 256M, cpus: "0.25" }
hil-telemetry:
deploy:
resources:
limits: { memory: 256M, cpus: "0.5" }
hil-ota-service:
deploy:
resources:
limits: { memory: 128M, cpus: "0.25" }
hil-mqtt-bridge:
deploy:
resources:
limits: { memory: 128M, cpus: "0.25" }

Expected resource usage:

  • Total RAM: ~1.5GB
  • Total CPU: ~2 cores
  • MQTT messages/sec: ~50 (1 per device per second)
  • Redis memory: ~50MB

Agriculture (500 Sensors)​

An agricultural deployment with 500 soil/weather sensors:

# Scale telemetry and fleet for high sensor count
services:
hil-device-fleet:
deploy:
replicas: 2
resources:
limits: { memory: 512M, cpus: "1.0" }
hil-telemetry:
deploy:
replicas: 3
resources:
limits: { memory: 1G, cpus: "2.0" }
redis:
command: >
redis-server --appendonly yes
--maxmemory 1gb
--maxmemory-policy allkeys-lru

Key considerations:

  • Telemetry pipeline needs 3 replicas for 500 sensors at 1 reading/second
  • InfluxDB storage: ~2GB/day at 500 readings/second
  • Retention policy: 7 days raw, forever aggregated
  • MQTT topic partitioning by field zone

Industrial (1000 PLCs)​

An industrial deployment with 1000 PLCs on a manufacturing floor:

services:
hil-api-gateway:
deploy:
replicas: 3
environment:
RATE_LIMIT_MAX: 500
hil-device-fleet:
deploy:
replicas: 2
environment:
HEARTBEAT_TIMEOUT_MS: 10000
FLEET_SCAN_INTERVAL_MS: 5000
hil-telemetry:
deploy:
replicas: 5
environment:
AGGREGATION_WINDOWS: "10,60,300"
RETENTION_DAYS: 90
hil-ota-service:
deploy:
replicas: 2
environment:
CANARY_PERCENT: 2
ROLLOUT_STAGES: "2,10,25,50,75,100"
redis:
command: >
redis-server --appendonly yes
--maxmemory 4gb
--maxmemory-policy volatile-lru
influxdb:
volumes:
- influxdb-data:/var/lib/influxdb2
deploy:
resources:
limits: { memory: 4G, cpus: "4.0" }

Key considerations:

  • Shorter heartbeat timeouts for critical industrial equipment
  • Aggressive telemetry aggregation (10-second windows)
  • Lower canary percentage for safety-critical rollouts
  • 90-day data retention for compliance
  • Dedicated Redis with 4GB memory

Kubernetes Production Deployment​

Helm Chart Structure​

# hil-platform/values.yaml
replicaCount:
apiGateway: 3
deviceFleet: 2
telemetry: 5
otaService: 2
mqttBridge: 3

resources:
apiGateway:
requests: { cpu: 250m, memory: 256Mi }
limits: { cpu: 1000m, memory: 512Mi }
telemetry:
requests: { cpu: 500m, memory: 512Mi }
limits: { cpu: 2000m, memory: 1Gi }

autoscaling:
enabled: true
minReplicas: 2
maxReplicas: 10
targetCPUUtilization: 70
targetMemoryUtilization: 80

Horizontal Pod Autoscaling​

# k8s/hpa.yaml
apiVersion: autoscaling/v2
kind: HorizontalPodAutoscaler
metadata:
name: hil-telemetry-hpa
spec:
scaleTargetRef:
apiVersion: apps/v1
kind: Deployment
name: hil-telemetry
minReplicas: 3
maxReplicas: 15
metrics:
- type: Resource
resource:
name: cpu
target:
type: Utilization
averageUtilization: 70
- type: Resource
resource:
name: memory
target:
type: Utilization
averageUtilization: 80

MQTT Topic Partitioning​

For large-scale Kubernetes deployments, partition MQTT topics across broker instances:

Zone A devices → mosquitto-a:1883
Zone B devices → mosquitto-b:1883
Zone C devices → mosquitto-c:1883

Each telemetry replica subscribes to a specific zone
# Partitioned telemetry deployment
apiVersion: apps/v1
kind: Deployment
metadata:
name: hil-telemetry-zone-a
spec:
replicas: 3
template:
spec:
containers:
- name: telemetry
env:
- name: MQTT_BROKER
value: "mqtt://mosquitto-a:1883"
- name: TOPIC_FILTER
value: "hil/device/zone-a/+/telemetry"

Monitoring​

Prometheus + Grafana Stack​

Add monitoring with Prometheus scraping /health and custom metrics endpoints:

# docker-compose.monitoring.yml
services:
prometheus:
image: prom/prometheus:latest
ports: ["9090:9090"]
volumes:
- ./monitoring/prometheus.yml:/etc/prometheus/prometheus.yml
networks: [hil-net]

grafana:
image: grafana/grafana:latest
ports: ["3000:3000"]
environment:
GF_SECURITY_ADMIN_PASSWORD: ${GRAFANA_PASSWORD:-admin}
volumes:
- grafana-data:/var/lib/grafana
networks: [hil-net]

Key Metrics to Monitor​

MetricServiceAlert Threshold
mqtt_connected_clientsMosquitto< expected count
device_online_percentageFleet< 90%
telemetry_processing_rateTelemetry< 100 msg/sec
anomaly_detection_rateTelemetry> 10/sec
ota_failure_rateOTA> 5%
ws_active_connectionsBridge> max * 0.9
http_request_latency_p99Gateway> 500ms
redis_memory_usageRedis> 80%

Structured Logging​

All services emit structured JSON logs:

{
"service": "hil-telemetry",
"level": "info",
"message": "Anomaly detected",
"deviceId": "hil-001",
"sensor": "temperature",
"value": 135.2,
"threshold": 125,
"severity": "critical",
"timestamp": "2024-11-14T12:00:00.000Z"
}

Security​

API Key Authentication​

All API endpoints require an X-API-Key header:

curl -H "X-API-Key: your-256-bit-key" http://localhost/api/gateway/devices

Generate a secure key:

export API_KEY=$(openssl rand -hex 32)

JWT Token Support​

For multi-tenant deployments, extend the Gateway with JWT validation:

// Add to gateway middleware
const jwt = require("jsonwebtoken");

function jwtAuth(req, res, next) {
const token = req.headers.authorization?.replace("Bearer ", "");
if (!token) return res.status(401).json({ error: "No token provided" });

try {
const decoded = jwt.verify(token, JWT_SECRET);
req.user = decoded;
next();
} catch {
return res.status(401).json({ error: "Invalid token" });
}
}

mTLS Between Services​

For zero-trust networking, configure mutual TLS between all services:

# In docker-compose.yml, mount certificates
services:
hil-api-gateway:
volumes:
- ./certs/ca.crt:/app/certs/ca.crt:ro
- ./certs/gateway.crt:/app/certs/server.crt:ro
- ./certs/gateway.key:/app/certs/server.key:ro
environment:
TLS_CA: /app/certs/ca.crt
TLS_CERT: /app/certs/server.crt
TLS_KEY: /app/certs/server.key

MQTT Authentication​

Configure Mosquitto with password authentication:

# Create password file
docker exec hil-mosquitto mosquitto_passwd -c /mosquitto/config/password.txt admin
docker exec hil-mosquitto mosquitto_passwd -b /mosquitto/config/password.txt device-pass

Network Isolation​

Docker Compose isolates the internal network. Only nginx exposes ports externally. Services communicate on the hil-net bridge network and cannot be reached from outside Docker.

Scaling Guide​

Horizontal Scaling Rules​

ServiceScale WhenMax Replica Guidance
API GatewayCPU > 70%, p99 latency > 500ms2-5 replicas
Device Fleet> 500 devices, CPU > 60%1-3 replicas
TelemetryIngest rate > capacity, CPU > 70%3-15 replicas
OTA ServiceActive campaign + high device count1-3 replicas
MQTT BridgeWS connections > 80% max2-5 replicas

Scaling MQTT​

Mosquitto is the bottleneck for message throughput. Options:

  1. Vertical scaling: Increase Mosquitto resources (easiest)
  2. Clustering: Use MQTT brokers with shared subscriptions
  3. Topic partitioning: Split devices across broker instances
  4. Alternative brokers: Consider EMQX or VerneMQ for > 10K devices

Scaling Redis​

For large device fleets (> 1000 devices):

  1. Use Redis Cluster with sharding
  2. Configure maxmemory appropriately
  3. Use allkeys-lru eviction for cache workloads
  4. Monitor with redis-cli INFO memory

Scaling InfluxDB​

For high telemetry throughput:

  1. Use InfluxDB Enterprise or Cloud for clustering
  2. Configure continuous queries for downsampled data
  3. Set appropriate shard group durations
  4. Use separate retention policies per data type

References​

  • Newman, S. (2021). Building Microservices: Designing Fine-Grained Systems (2nd ed.). O'Reilly Media.
  • Richardson, C. (2018). Microservices Patterns: With Examples in Java. Manning Publications.
  • Burns, B., & Beda, J. (2024). Kubernetes: Up and Running (3rd ed.). O'Reilly Media.
  • Hohpe, G., & Woolf, B. (2003). Enterprise Integration Patterns. Addison-Wesley.
  • Ford, N., & Richards, M. (2020). Release It! Design and Deploy Production-Ready Software (2nd ed.). Pragmatic Bookshelf.
  • Antanies, J. (2022). IoT with MQTT: A Practical Guide to the Message Queuing Telemetry Transport Protocol. Packt Publishing.
  • Vasquez, M. (2023). The IoT Handbook: Build IoT Solutions with MQTT, Raspberry Pi, and Node-RED. Apress.
  • Richardson, C., & others (2023). Microservices: Pattern by Example. microservices.io.
  • Mosquitto Project (2024). Eclipse Mosquitto v2.0 Documentation. https://mosquitto.org/documentation/
  • InfluxData (2024). InfluxDB v2.7 Documentation. https://docs.influxdata.com/influxdb/v2.7/